  • PXI Power Supply 1 Channel 40W 48V 2A

    PS48401 - LXinstruments GmbH

    The PS48401 is a programmable DC power supply in a 2-slot PXI/cPCI form factor. It features a fully isolated output capable of delivering 0-48VDC / 2A / 40W. It offers a programmable current limit and the ability to measure the output voltage and current under software or trigger control.

  • Turn-Key Short Circuit Laboratories

    Hilkar

    For low and medium voltage switchgear including :*Circuit breakers*Contactors*Disconnect switches*Fuses*Miniature circuit breakersApplied tests for low and medium voltage switchgear :*Dielectric withstand test*Impulse withstand test*Breaking capacity test*Mechanical life testElectrical life test*Over load performance test*Short circuit breaking capacity test**Short time short circuit impulse current test*Temperature rise test*Operation performance testTests for low & medium voltage panels :*Short time short circuit impulse current test*Dielectric test*Impulse withstand voltage test*Temperature rise test

  • Precision Power Amplifier

    Dr. Hubert GmbH

    The main features of our power amplifiers are extreme broadband, low distortion and stability, above all. All amplifiers are operated and parameterized via a comfortable application software. The basic devices are mere voltage suppliers and provide 2 supply voltages and a USB interface.The letter "E" in the model name represents additional features: the amplifiers can optionally be operated as voltage amplifier or current amplifier; there are monitor outputs for voltage and current, and there are 3 symmetrical supply voltages available for optional selection.The amplifiers from the QE range provide "auto-commutating" voltage supply. In contrast to the E-models, 3 bipolar supply voltages are individually switched either automatically or manually.The QE-models provide highest sink outputs and are thus also suitable for operation as active load.For detailed information on HUBERT amplifier technology please see our White Paper No.1: HUBERT power amplifiers.

  • AC / DC Current Clamp

    HT9025 - HT Italia Srl

    HT9025 has been designed to measure AC/DC current up to 1000A, DC voltage up to 1500V and AC voltage up to 1000V in TRMS reaching CAT IV 600V and CAT III 1000V in compliance with safety standard IEC/ EN61010-1.

  • Low Resistance Ohm Meter

    6237 DLRO - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● Measure down to 1μΩ.● 6 ranges from 2.000mΩ to 200.0Ω.● Maximum resolution of 1μΩ.● Three test currents with over-temperature protection.● Four terminal measurement.● Protection against inadvertent connection to over- voltage. (crow bars for current and voltage)● Clear & large LCD.● Potential lead resistance and current lead resistance checks.● "Full-featured” EnerSave™ Inside.● EnerSave™ Auto-hold.● EnerSave™ Auto-off.● Rechargeable battery operated● Robust & compact.● Indicators show if reading may be invalid (RP, RC, and temperature).● "O-Ring” sealed case.

  • True RMS AC Voltage/Current Datalogger

    Extech DL150 - Extech Instruments Corporation

    The DL150 is a True RMS AC voltage and current data logger. Data log up to 100,000 readings of TRMS AC Voltage (600) or Current (200 Amp) with a user programmable sample rate from 1 second to 24 hours. LCD displays time/date, current reading, min/max, and if the user settable high/low alarms have been exceeded. Readings can be downloaded to your PC via the USB interface. Featuring Normal, Peak, and Capture (user specified trigger level) recording modes. Complete with current clamp, test leads, alligator clips, software, USB cable, 110-Volt AC Adapter, and four (4) AAA batteries.

  • Universal Multichannel System up to 500V

    CAEN S.p.A.

    - From 12 to 48 independently controllable High Voltage channels- 0 ÷ 500 V output voltage (0 ÷ 250 V, A1519B and A1619 only)- Maximum Current 0.5, 1, 10 mA or 1 mA/100 μA (dual range boards)- Individual Enable (A151x only)- Either DB37, DB25, Radiall Multipin or SHV connectors- Available with either positive, negative or mixed polarity- Up to 20 nA, 100 pA current set / monitor resolution- Up to 10 mV / 1 mV voltage set / monitor resolution- Very Low ripple, down to < 5 mVpp- 3 different channel grounding - Common Ground (AGxxxx) - Common Floating Return (Axxxx) - Full Floating (A151x, A1612, A1619)- Independently programmable for each channel: - Output voltage - Current limit - Ramp up/down - TRIP parameter- Current generator operation in overcurrent condition- Specific design for double side silicon detector (A151x)

  • Curve Tracer

    CS-5000 Series - Scientific Test, Inc.

    Maximum peak voltage: 5,000V (high-voltage mode for all models) in CS-5000 Series. Maximum peak current: 1,000A (CS-5300 high-current mode). The CS-5000 Series achieves 5,000V of max. peak voltage with the same physical size as the CS-3000 Series. Best suited for the measurement of a power devices that have 3.3kV and 4.5kV withstanding voltage.

  • Lightning Current Generator

    Shanghai Guantu Technology Co., Ltd.

    The lightning wave impulse current generator is an impulse current generator that generates a simulated lightning current waveform . Its working process is as follows: first, the transformer charges the capacitor bank through the silicon pile, when the charging voltage reaches a predetermined value, the spark gap is triggered, and the capacitor is discharged through the total inductance and total resistance of the circuit. When the resistance is greater than or equal to the critical damping value, a unidirectional impulse current wave is generated in the circuit. When the resistance is less than the critical damping value, an oscillating impulse current wave is generated. The magnitude of the impact current amplitude is related to the circuit parameters. When the capacitance value and charging voltage are the same, the smaller the inductance value, the greater the current amplitude. In order to obtain as much current as possible, a pulse capacitor with a small inductance value is usually selected, and the total length of the connecting line should be as short as possible when arranging the main capacitor, so that the total loop inductance value can be reduced as much as possible.

  • Fully Automatic Close Link Single Phase Energy Meter Test bench

    SY8125 - Hong Kong Songyang Industrial Ltd.

    The devices are fully made by aluminum alloy materials and the table board is composed of fireproofing and heat-proof materials. ● The output voltage and current use soft startup and stop. It has the protection functions of voltage short circuit, current open circuit and power amplification exception.● The device has the features of high stability, good reliability and large output power. ● High level of autoimmunization. The coexistence of special small keyboard and PCs, convenience to use.

  • Multi-Channel Telemetry

    Accumetrics Associates, Inc.

    The AT7000 multi-channel systems can combine any customized mix of ordinary sensors: strain gages, thermocouples, RTDs, accelerometers, as well as motor/generator field voltages, currents and ground fault currents. The received data is continuously streamed to the user as analog (+/- 10V or 4/20mA) or digital data.

  • AC Power Analyzers

    Keysight Technologies

    Measure voltage, current and power on 4 channels: DC, 1-phase AC or 3-phase ACMake more accurate power measurements: 0.05% at 50/60 HzMeasure current directly: internal shunts to 50 Arms, or with external probes or transducersAddress multiple test scenarios with isolated inputs

  • AC/DC Digital Clamp Tester (CE)

    M-260 - MULTI MEASURING INSTRUMENTS Co., Ltd.

    *Wide current measurements with tear drop type 55mmφCT up to 2000A.*Data-hold and Auto power off function.*Additional AC/DC voltage, resistance, diode test, continuity check.*Auto zero adjustment for DC current offset.*Conform to IEC safety requirements.

  • Inductive Load Tester

    4602-LV - TESEC, INC

    There is a tendency that MOSFET has Low On Resistance so that it demands that Inductive Load Tester to have higher forcing current for measurement. The forcing current is limited by forcing voltage with previous test method. Thus it becomes difficult to test this kind of middle power range devices.

  • Current Tester

    MIG0624 - EMC Partner AG

    The MIG0624 current tester is designed to test surge protection devices for low voltage applications (<1000 V). MIG0624 is a current generator delivering a 8/20 µs impulse up to 24kA. The exact waveform delivered is a function of the surge generator and the impedance to which the surge is applied.